Description
PHILIPS GreenPerform Cleanroom LED Panel CR500C Series
Surface-mounted cleanroom panel in four footprints — 600 × 600, 600 × 260, 1,190 × 260 and 1,200 × 600 mm — 2,500 to 6,000 lm at 100 lm/W, 3000 / 4000 / 6500 K, 13 mm body on a slide-in ceiling bracket.
Pick the footprint first, then the colour temperature
Fifteen order codes: five footprint and power combinations, each in three colour temperatures. The matrix below is the shortcut — find the size your ceiling module already is, then read across to the 12NC you need.
| Footprint · power | 3000 K · 830 | 4000 K · 840 | 6500 K · 865 |
|---|---|---|---|
| 600 × 26025 W · 2,500 lm | 911401512744 | 911401512644 | 911401512844 |
| 1,190 × 26040 W · 4,000 lm | 911401513044 | 911401512944 | 911401513144 |
| 600 × 60025 W · 2,500 lm | 911401513344 | 911401513244 | 911401513444 |
| 600 × 60040 W · 4,000 lm | 911401513644 | 911401513544 | 911401513744 |
| 1,200 × 60060 W · 6,000 lm | 911401513944 | 911401513844 | 911401514044 |
3000 K is what most pharmaceutical production and ward areas ask for; 4000 K is the neutral white used for GMP inspection benches; 6500 K is the local convention in electronics and semiconductor plants where the ceiling is expected to read cool.
Why a cleanroom ceiling takes a surface panel, not a recessed one
Fig. 01 — Classified corridor: CR500C panels sit whole below a sealed sandwich-panel ceiling, so the room boundary is never cut.
In an ISO 7 or ISO 8 room the ceiling is not a ceiling — it is the pressure boundary. A recessed panel needs a cut-out, and every cut-out needs a gasket, a flush trim and its own cleaning routine, because the void above the room is a technical space that nobody wipes. Install a hundred of them and you have a hundred places where the boundary can fail at the next qualification.
CR500C removes the whole discussion. The bracket fixes to the ceiling, the panel slides onto it, and the luminaire stays completely on the room side: the only joint is one continuous line around a 13 mm body, and it can be wiped in the same pass as the wall. Nothing enters the plenum, and nothing above the ceiling needs to be cleaned to keep the room in class.
This is also why the body is 13 mm and the driver is separate. The depth goes to the diffuser and the frame, not to electronics, so the panel sits tight to the ceiling — and a failed driver is replaced without opening the room.
Four footprints, one 13 mm body
The range is built around the two module sizes cleanroom ceilings actually use, plus the two narrow bodies for corridors and light lines.

600 × 600 · 25 / 40 W
The standard 600 module, 2,500 lm or 4,000 lm from the same housing. One panel per grid square, no trim ring, no cut-out.

1,200 × 600 · 60 W
6,000 lm for a full 1.2 m bay. On a large open production floor this is the code that keeps the panel count and the ceiling joints down.

1,190 × 260 · 40 W
The long narrow body, 4,000 lm. 1,190 mm is 10 mm under a 1,200 mm module, which is the clearance most installers want at the wall line.
The fourth footprint is 600 × 260 mm at 25 W and 2,500 lm — the short version of the same 260 mm profile, for corridor runs and light lines where a full module will not fit. Its outline is the bottom drawing in Fig. 05.
Outlines, depth and overall height
Fig. 05 — Section outlines for all four footprints. H is the 13 mm body, H1 the 38 mm overall height once the slide-in bracket is on.
| Order code | L (mm) | W (mm) | H (mm) | H1 (mm) |
|---|---|---|---|---|
| CR500C LED60 W60L120 PSU | 1,200 | 600 | 13 | 38 |
| CR500C LED40 W26L119 PSU | 1,190 | 260 | 13 | 38 |
| CR500C LED25 W60L60 PSU | 600 | 600 | 13 | 38 |
| CR500C LED40 W60L60 PSU | 600 | 600 | 13 | 38 |
| CR500C LED25 W26L60 PSU | 600 | 260 | 13 | 38 |
H1 is what matters to the ceiling: 38 mm below the slab or sandwich panel, bracket included. Allow for the driver, which is external to the panel.
The six parts that decide whether it stays clean
Sloped frame
The frame edge is angled, not a flat ledge. Air from the ceiling diffusers passes it without depositing, and there is no horizontal shelf for dust to land on between wipes.
IP54 face, IP40 body
The lit face is sealed for wipe-down and spray; the side that faces the ceiling stays IP40. The rating follows the cleaning routine instead of over-specifying the whole luminaire.
Prismatic PS bowl
A textured polystyrene diffuser spreads the LEDs into one even face. Staff working under twenty of these see a surface, not a grid of dots.
SDCM ≤ 5
A cleanroom ceiling is a continuous field of luminaires, so a colour step between two panels is visible from the door. Five-step consistency keeps the field uniform.
Flicker ≤ 4 %
Low enough for visual inspection benches and for cameras on a filling line, where flicker shows as banding rather than as something the eye can name.
Separate driver
The light engine and the driver are two parts. Maintenance swaps the driver, not the luminaire — no ceiling work, no re-qualification of the room.
Where it is specified
Pharmaceutical production
Dispensing, granulation, filling and packing halls. 4000 K at 300–500 lx on the work plane is the usual brief; the sealed face takes the daily detergent wipe without a second enclosure.
Electronics and semiconductor
Where the ceiling has to stay cool in colour and the room runs at 6500 K. The low body depth keeps the panel out of the way of the air path from FFU ceilings.
Food and beverage
High-care packing and preparation rooms. The IP54 face handles wash-down of the ceiling line; the sloped frame leaves no ledge above an open product zone.
Hospitals and clean wards
Operating theatre corridors already built to a sealed ceiling, and wards where a surface panel is the only option because nobody will reopen the slab.
CR500C covers the surface-mounted cleanroom ceiling. For walls and open wash-down zones the PHILIPS tri-proof range is the normal companion, for solvent and powder atmospheres the explosion-proof range, and the rest of the indoor programme sits under PHILIPS LED panels.
Technical specifications
| Parameter | 600 × 260 | 1,190 × 260 | 600 × 600 | 1,200 × 600 |
|---|---|---|---|---|
| Optical | ||||
| System power (typ.) | 25 W | 40 W | 25 / 40 W | 60 W |
| Luminous flux (typ.) | 2,500 lm | 4,000 lm | 2,500 / 4,000 lm | 6,000 lm |
| System efficacy (typ.) | 100 lm/W standard · 120 lm/W on request | |||
| Flux tolerance | ±10 % | |||
| Colour temperature | 3000 K (830) / 4000 K (840) / 6500 K (865) | |||
| Colour rendering | CRI ≥ 80 | |||
| Colour consistency | SDCM ≤ 5 | |||
| Light distribution | Lambertian, wide beam, 120° | |||
| Flicker | ≤ 4 % | |||
| Electrical | ||||
| Input voltage | 220–240 V · 50/60 Hz | |||
| Power factor | ≥ 0.9 | |||
| Total harmonic distortion | ≤ 10 % | |||
| Protection class | Class II | |||
| Driver | Separate driver (PSU), fixed output | |||
| Dimming | No | |||
| Mechanical | ||||
| Dimensions L × W | 600 × 260 mm | 1,190 × 260 mm | 600 × 600 mm | 1,200 × 600 mm |
| Body height H / overall H1 | 13 mm / 38 mm | |||
| Housing | Metal and plastic, white and grey | |||
| Diffuser | Polystyrene bowl, prismatic, textured finish | |||
| Mounting | Surface mounted, slide-in ceiling bracket | |||
| Environment and approval | ||||
| Ingress protection | IP54 light-emitting face / IP40 complete luminaire | |||
| Impact protection | IK02 (0.2 J) | |||
| Ambient temperature | −20 to +45 °C (Ta 35 °C) | |||
| Lifetime | 50,000 h L70B50 at 35 °C | |||
| Certification | CCC | |||
| Pack quantity | 1 piece per inner, 4 pieces per outer carton | |||
Values are typical and carry a ±10 % tolerance, as published for this range. IES, LDT and ULD photometric files are supplied on request — this page does not reproduce a measured polar curve, because a redrawn curve is not a measurement.
Complete product lineup
Fifteen 12NCs. Order by the code in the first column; the model description is the factory order string and is quoted exactly as published.
| 12NC | Description | Power | L × W | Output | CCT |
|---|---|---|---|---|---|
| 911401512644 | CR500C LED25/840 W26L60 PSU | 25 W | 600 × 260 | 2,500 lm | 840 |
| 911401512744 | CR500C LED25/830 W26L60 PSU | 25 W | 600 × 260 | 2,500 lm | 830 |
| 911401512844 | CR500C LED25/865 W26L60 PSU | 25 W | 600 × 260 | 2,500 lm | 865 |
| 911401512944 | CR500C LED40/840 W26L119 PSU | 40 W | 1,190 × 260 | 4,000 lm | 840 |
| 911401513044 | CR500C LED40/830 W26L119 PSU | 40 W | 1,190 × 260 | 4,000 lm | 830 |
| 911401513144 | CR500C LED40/865 W26L119 PSU | 40 W | 1,190 × 260 | 4,000 lm | 865 |
| 911401513244 | CR500C LED25/840 W60L60 PSU | 25 W | 600 × 600 | 2,500 lm | 840 |
| 911401513344 | CR500C LED25/830 W60L60 PSU | 25 W | 600 × 600 | 2,500 lm | 830 |
| 911401513444 | CR500C LED25/865 W60L60 PSU | 25 W | 600 × 600 | 2,500 lm | 865 |
| 911401513544 | CR500C LED40/840 W60L60 PSU | 40 W | 600 × 600 | 4,000 lm | 840 |
| 911401513644 | CR500C LED40/830 W60L60 PSU | 40 W | 600 × 600 | 4,000 lm | 830 |
| 911401513744 | CR500C LED40/865 W60L60 PSU | 40 W | 600 × 600 | 4,000 lm | 865 |
| 911401513844 | CR500C LED60/840 W60L120 PSU | 60 W | 1,200 × 600 | 6,000 lm | 840 |
| 911401513944 | CR500C LED60/830 W60L120 PSU | 60 W | 1,200 × 600 | 6,000 lm | 830 |
| 911401514044 | CR500C LED60/865 W60L120 PSU | 60 W | 1,200 × 600 | 6,000 lm | 865 |
Colour codes: 830 = 3000 K, 840 = 4000 K, 865 = 6500 K. Every code is the 100 lm/W version; the 120 lm/W build is quoted per project.
Also from the PHILIPS range
Frequently asked questions
Can CR500C be recessed into a cleanroom ceiling?
No. CR500C is a surface-mounted luminaire and its bracket is designed for that position only. In a classified room the ceiling is normally the sealed boundary, so a recessed panel would need its own cut-out, gasket and trim. If your drawing already shows a recessed module, use a recessed panel range instead of forcing CR500C into the opening.
What is the difference between IP54 on the face and IP40 on the body?
The light-emitting face is sealed to IP54, which is the surface that gets wiped and washed during a cleanroom routine. The housing and the cable entry behind it are IP40, because they sit against the ceiling and are never sprayed. Both ratings appear on the label: IP54 front side, IP40 complete luminaire.
Which CR500C size fits a standard 600 × 600 ceiling grid?
The W60L60 codes. That footprint is 600 × 600 mm with a 13 mm body, and it comes in 25 W (2,500 lm) and 40 W (4,000 lm), each in 3000 K, 4000 K and 6500 K. The 1,200 × 600 code covers one 1.2 m bay, and the two 260 mm wide codes are for corridor runs and narrow light lines.
Is the 120 lm/W version a separate order code?
It is a configured option, not a catalogue code. The standard range is 100 lm/W and every 12NC in the table below is that version. For 120 lm/W we quote per project against the quantity and the colour temperature you need, so ask us before you write the order code into a tender.
How is the driver maintained if it fails?
CR500C uses a separate driver: the panel carries the light engine and the driver sits outside it, so a driver change does not mean dismantling a cleanroom ceiling around a sealed luminaire. That is also why the body is only 13 mm deep - the depth is spent on the panel, not on electronics.

RC468V Frameless Panel
RC168 Frameless Panel
RC038V Backlit Panel
RC430 Aura Panel
RC430V Aura DALI Panel
WT198C G3 Waterproof
RC052 G2 Ceiling Light
BY690P Cold Room Highbay