WENZHOU HONNEX TRADING CO.,LTD
  • Home
  • Products
    • PHILIPS indoor Lighting
      • PHILIPS LED Downlight
      • PHILIPS LED Batten
      • PHILIPS LED Spot Light
      • PHILIPS LED Lamp
      • PHILIPS LED Linear Light
      • PHILIPS LED Strip
      • PHILIPS LED tube
      • PHILIPS LED Lowbay
      • PHILIPS LED Highbay
      • PHILIPS LED Ceiling Light
      • PHILIPS LED Tri-proof light
      • PHILIPS LED Track Light
      • PHILIPS LED Panel
      • PHILIPS LED Bracket
    • PHILIPS outdoor Lighting
      • PHILIPS LED Street Light
      • PHILIPS Wall Light
      • PHILIPS LED Floodlight
      • PHILIPS LED Tunnel Light
      • PHILIPS LED Lawn Light
      • PHILIPS LED Point Light
      • PHILIPS LED Wall Washer Light
      • PHILIPS LED GARDEN Light
      • PHILIPS LED UNDERGROUND Light
    • PHILIPS Traditional Light
      • PHILIPS Tube
      • PHILIPS Tri-Proof
      • PHILIPS HID
    • PHILIPS Hue Smart LED
    • PHILIPS Special Lighting
      • PHILIPS TUV
      • PHILIPS Infrared light
    • Signify
      • Signify LED Street Light
    • Starsense LED Lighting
    • Starsense Traditional Light
    • Honnex LED Lighting
      • Honnex LED Panel
      • Honnex LED Street Light
      • Honnex LED Flood Light
      • Honnex LED Tunnel Light
    • PHILIPS OEM Accessories
      • PHILIPS Indoor Driver
      • PHILIPS Outdoor Driver
      • PHILIPS LED Chips
      • PHILIPS LED MODULE
  • News
    • Company news
    • Blog
    • Industry-news
  • Download
  • Contact us
  • About us

PHILIPS Sensor LEDtube 1200mm 18W 840 T8 G2 CN 929004435410

  1. Home
  2. Products
  3. PHILIPS indoor Lighting
  4. PHILIPS LED tube
  5. PHILIPS Sensor LEDtube 1200mm 18W 840 T8 G2 CN 929004435410
  • PHILIPS Sensor LEDtube 1200mm 18W 840 T8 G2 CN 929004435410 - Image 1

PHILIPS Sensor LEDtube 1200mm 18W 840 T8 G2 CN 929004435410

  • Product Item:929004435410
  • Rated Power & Voltage:  18W / 220-240V ~ 50/60Hz
  • Light Output & Efficacy:  2,100 lm / 116 lm/W / 240° beam
  • Sensor & Control:  5.8GHz motion + 2.4GHz mesh / 100%-20% dim
  • Lifetime & Safety:  50,000h L70 / PF 0.9 / RG0
  • PHILIPS , LEDtube , Sensor , G13 , 18W , 4000K
    Inquiry Send Email

    Description

    PHILIPS Sensor LEDtube 1200mm 18W 840 T8 G2 CN 929004435410

    • PHILIPS
    • 929004435410
    • 18 W
    • 4,000 K
    • 2,100 lm
    • 240°
    • G13
    • T8 · 1,200 mm

    1,200 mm T8 retrofit tube with a 5.8 GHz presence sensor and a 2.4 GHz inter-luminaire link. Holds 20 % output in empty hours, returns to 2,100 lm the moment a person or vehicle enters the bay — no app, gateway, battery or commissioning.

    2,100 lm

    full output on detection

    116 lm/W

    rated efficacy

    100 → 20 %

    auto-dim after 60 s

    50,000 h

    nominal lifetime, L70

    Two sensors inside one tube

    One sensor watches the space, the other talks to the neighbouring tubes. That is what removes the blind spot you get with a single stand-alone sensor tube.

    5.8 GHz presence detection

    Detects people and vehicles moving under the tube and drives the output to 100 %. Because the sensing element sits inside the lamp, nothing is mounted on the ceiling and nothing needs pairing.

    2.4 GHz inter-luminaire communication

    The triggered tube broadcasts to neighbouring luminaires within roughly 10 m, so the whole run lights ahead of the occupant instead of one tube at a time.

    5.8 GHz PRESENCE DETECTION — SIDE ELEVATION h 0.5-4 m r ≈ 3-5 m at h = 2.8 m 2.4 GHz MESH — PLAN VIEW 100 % 20 % 20 % signal radius ≈10 m in-range tubes lift to full output · outer tubes hold 20 %

    Coverage geometry as published for the Sensor LEDtube G2: recommended mounting height h = 0.5-4 m, typical detection radius r ≈ 3-5 m at h = 2.8 m, inter-luminaire signal radius ≈10 m. Indicative diagram, not a measured photometric file; real coverage varies with the installation environment.

    • Recommended mounting height h = 0.5 m to 4 m
    • Typical detection radius r ≈ 3-5 m at h = 2.8 m
    • 60 s without motion returns the tube to 20 %
    • Battery-free, no software update, no grouping setup
    • Detection range follows the real mounting height
    • Signal range varies with the installation environment

    What the automatic dimming saves

    Annual consumption for the same 1,200 mm slot, measured over 8,760 hours of operation.

    Baseline

    36 W TL-D fluorescent on a 9 W magnetic ballast

    394 kWh / year

    →
    This luminaire

    Sensor LEDtube 18 W — 8 h occupied per day

    74 kWh / year

    81 % lower
    Baseline

    36 W TL-D fluorescent on a 9 W magnetic ballast

    394 kWh / year

    →
    This luminaire

    Sensor LEDtube 18 W — 12 h occupied per day

    95 kWh / year

    76 % lower
    Baseline

    Standard 18 W LED tube, no sensor

    158 kWh / year

    →
    This luminaire

    Sensor LEDtube 18 W — 8 h occupied per day

    74 kWh / year

    53 % lower

    Basis: 24 h per day, 8,760 h per year, full output during the occupied hours stated and 20 % output for the remainder. Moving up from the previous generation? The PHILIPS Sensor LEDTUBE 1200 mm 14 W 1600 lm (929001399710) is still catalogued and uses the same G13 caps — see the 14 W 1600 lm version.

    Why it fits a retrofit project

    No controls layer, no commissioning step, no new luminaire.

    Installs like an ordinary tube

    Same 1,200 mm length, same G13 caps, same luminaire. No new wiring layout and no control cable to pull.

    Route stays visible when empty

    20 % standby keeps the floor line, the exit signs and the camera scene readable between visits.

    240° wide beam

    Light leaves the tube upwards and sideways, not only downwards, so a single ceiling run covers the bay evenly.

    Nothing to maintain

    No battery to replace, no gateway to power, no firmware to update — the sensor lives inside the lamp for its full 50,000 h.

    Fit and wiring

    Straight replacement of a 1,200 mm T8 lamp in an existing G13 luminaire. The tube runs on mains, so the ballast is either kept as a magnetic choke or bypassed.

    Magnetic ballast luminaire (EM)

    1. Switch the circuit off.
    2. Remove the compensation capacitor to improve the power factor.
    3. Take out the fluorescent tube and its starter.
    4. Fit the PHILIPS LED starter EP in place of the fluorescent starter.
    5. Insert the Sensor LEDtube G2 and switch on.

    Electronic ballast luminaire (HF)

    1. Switch the circuit off.
    2. Bypass the ballast and any starter.
    3. Rewire the L and N supply straight to the LEDtube, observing the L/N marking.
    4. Insert the tube in the luminaire without changing the luminaire itself.
    5. Switch on and confirm the tube reaches full output on detection.
    Before you install: not for use with dimmers; 50/60 Hz supply only; dry indoor conditions or a luminaire that provides protection against water; ambient -20 to +45 °C; the PHILIPS LED starter EP is not interchangeable with other brands. The lamp is not suitable for every application in which a traditional fluorescent lamp was used — check the installation conditions first.

    Technical specifications

    Values below are the published data for 929004435410. Both colour temperatures share the same electrical and sensor platform.

    Parameter Value
    General
    Cap-Base G13
    Bulb Shape T8
    Lighting Technology LEDtube
    Wattage Equivalent 36 W
    Nominal Lifetime 50,000 h
    Switching Cycle 50,000
    Ambient Temperature Range -20 to +45 °C
    Light Technical
    Colour Code 840 [CCT of 4,000 K]
    Correlated Colour Temperature 4,000 K
    Colour Designation Cool White (CW)
    Luminous Flux 2,100 lm
    Luminous Efficacy (rated) 116 lm/W
    Beam Angle 240°
    Colour Rendering Index 80
    Colour Consistency ≤6 SDCM
    LLMF at End of Nominal Lifetime 70 %
    Photobiological Safety RG0 (EN 62471)
    Operating and Electrical
    Power Consumption 18 W
    Voltage (Nom) 220-240 V
    Input Frequency 50 to 60 Hz
    Lamp Current (Nom) 90 mA
    Power Factor 0.9
    Starting Time (Nom) 0.5 s
    Warm-up Time to 60 % Light 0.5 s
    Dimmable No — sensor auto-dim only
    Energy Consumption 18 kWh/1000 h
    Sensor and Control
    Presence Detection 5.8 GHz microwave
    Inter-luminaire Communication 2.4 GHz, radius ≈10 m
    Dimming Behaviour 100 % on motion, 20 % after 60 s
    Recommended Mounting Height 0.5 m to 4 m
    Typical Detection Radius 3-5 m at h = 2.8 m
    Battery / Gateway / App Not required
    Mechanical and Housing
    Bulb Finish Frosted
    Bulb Material Glass
    Product Length 1,200 mm (A1 1,199.4 mm)
    Tube Diameter (D1) 25.7 mm
    Net Weight (Piece) 0.200 kg
    Quantity per Outer Box 20
    Order Code 929004435410
    Material Nr. (12NC) 929004435410
    EAN/UPC - Product 6947830485673
    EAN/UPC - Case 6947830485680
    Approval and Application
    Approval Marks RoHS compliance
    EU RoHS Compliant Yes
    Energy Saving Product Yes
    Operating Mode EM / Mains

    Product gallery

    Product view and the three applications the tube was specified for.

    Sensor LEDtube G2 1200 mm T8 frosted glass tube shown in side view with G13 bi-pin caps
    Fig. 01 — 1,200 mm T8 frosted glass tube, G13 bi-pin capsSame 25.7 mm tube diameter as the fluorescent lamp it replaces
    Basement car park lit by sensor LED tubes while a pedestrian walks through the parking bay
    Fig. 02 — Basement car park: output raised as an occupant walks throughDetection to 100 % takes the run of tubes above the bay, not one tube
    Warehouse picking aisle under 1,200 mm sensor LED tubes mounted between the racking rows
    Fig. 03 — Low-bay warehouse aisle between racking rows240° beam spreads light up and sideways to reach the rack faces
    Empty back-of-house corridor where sensor tubes hold 20 percent standby output after the route clears
    Fig. 04 — Back-of-house corridor held at 20 % standbyThe route stays readable and camera-visible without full output

    Complete product lineup

    Two variants, one housing. The only difference is colour temperature.

    12NC Description Power CCT Output
    929004435410 Sensor LEDtube 1200mm 18W 840 T8 G2 CN 18 W 4,000 K 2,100 lm
    929004435510 Sensor LEDtube 1200mm 18W 865 T8 G2 CN 18 W 6,500 K 2,100 lm

    Both codes are quoted with 20 pieces per outer box. Browse the rest of the range on the PHILIPS LED tube category page.

    Also from the PHILIPS Lighting range

    Other linear and industrial luminaires specified alongside the Sensor LEDtube G2.

    PHILIPS CorePro LEDtube 1200 mm 14.5 W 840 — LED tube, G13 cap in the PHILIPS Lighting rangePHILIPS CorePro LEDtube 1200 mm 14.5 W 840
    PHILIPS MAS LEDtube 1200 mm HO 14 W 840 — high-output LED tube, G13 cap in the PHILIPS Lighting rangePHILIPS MAS LEDtube 1200 mm HO 14 W 840
    PHILIPS MASTER LEDtube 1200 mm HO 12.5 W 840 — MASTER high-output LED tube, G13 cap in the PHILIPS Lighting rangePHILIPS MASTER LEDtube 1200 mm HO 12.5 W 840
    PHILIPS Ecofit LEDtube 1200 mm 16 W 740 — value LED tube, G13 cap in the PHILIPS Lighting rangePHILIPS Ecofit LEDtube 1200 mm 16 W 740
    PHILIPS WT198C GreenPerform Waterproof G3 — IP65 tri-proof batten luminaire in the PHILIPS Lighting rangePHILIPS WT198C GreenPerform Waterproof G3
    PHILIPS BY778P GreenPerform Elite Highbay G2 — high-bay luminaire for racked storage in the PHILIPS Lighting rangePHILIPS BY778P GreenPerform Elite Highbay G2
    PHILIPS GreenPerform Trunking G2 LL130X — continuous-row trunking luminaire in the PHILIPS Lighting rangePHILIPS GreenPerform Trunking G2 LL130X
    PHILIPS WL008C LED10 NW oval Sensor — wall-mounted sensor bulkhead in the PHILIPS Lighting rangePHILIPS WL008C LED10 NW oval Sensor

    Frequently asked questions

    How far does the sensor reach?

    At the recommended 2.8 m mounting height the typical detection radius is 3-5 m. The tube can be installed anywhere between 0.5 m and 4 m, and the radius grows or shrinks with the height. The published range is typical, not guaranteed: ceiling material, columns and parked vehicles all shorten it.

    Does one tube light the whole run or only itself?

    One tube triggers its own output to 100 % and simultaneously sends a 2.4 GHz signal to neighbouring luminaires within roughly 10 m, so a run lights ahead of the occupant. Tubes outside that radius stay at 20 % until a neighbour or their own sensor picks up movement.

    Can I keep the existing ballast in the fixture?

    On a magnetic (EM) ballast you keep the choke, remove the compensation capacitor, replace the fluorescent starter with the PHILIPS LED starter EP and fit the tube. On an electronic (HF) ballast the ballast and starter are bypassed and L/N are wired straight to the tube. Do not use the tube on a dimmer circuit.

    Inquiry Us





    New Products

    PHILIPS MASTER LEDtube UltraEfficient Series T5

    PHILIPS MASTER LEDtube UltraEfficient Series T5

    PHILIPS Sensor LEDtube 1200mm 18W 865 T8 G2 CN 929004435510

    PHILIPS Sensor LEDtube 1200mm 18W 865 T8 G2 CN 929004435510

    PHILIPS MASTER LEDtube UltraEfficient MAS LEDtube 1500mm UE 18.9W 865 T5 EELB 929004352202

    PHILIPS MASTER LEDtube UltraEfficient MAS LEDtube 1500mm UE 18.9W 865 T5 EELB 929004352202

    PHILIPS MASTER LEDtube UltraEfficient MAS LEDtube 1500mm UE 18.9W 840 T5 EELB 929004352102

    PHILIPS MASTER LEDtube UltraEfficient MAS LEDtube 1500mm UE 18.9W 840 T5 EELB 929004352102

    Search

    Product Categories

      Feedback

      Send us a message and we will get back to you shortly.

      Contact Us

      • 8618906651079
      • 86-577-89887719
      • info@honnexlighting.com
      • live:jackhonghonnex
      • NO. 30 LIYANG NEW ROAD,LU CHENG,WENZHOU CHINA

      WhatsApp

      Scan to chat on WhatsApp.

      WhatsApp QR code

      Copyright © 2013-2026 WENZHOU HONNEX TRADING CO.,LTD All Rights Reserved.

      • Phone
      • Email
      • WhatsApp
      • Inquiry

      https://www.facebook.com/martin.ren.165https://www.youtube.com/channel/UCpPrjK99Pqt_29EdEsdCfvw/
      WhatsApp QR code
      WeChat QR code
      info@honnexlighting.com86-577-89887719
      Top
      WhatsApp
      Phone
      E-mail
      Inquiry