Description
PHILIPS Sensor LEDtube 1200mm 18W 840 T8 G2 CN 929004435410
- PHILIPS
- 929004435410
- 18 W
- 4,000 K
- 2,100 lm
- 240°
- G13
- T8 · 1,200 mm
1,200 mm T8 retrofit tube with a 5.8 GHz presence sensor and a 2.4 GHz inter-luminaire link. Holds 20 % output in empty hours, returns to 2,100 lm the moment a person or vehicle enters the bay — no app, gateway, battery or commissioning.
2,100 lm
full output on detection
116 lm/W
rated efficacy
100 → 20 %
auto-dim after 60 s
50,000 h
nominal lifetime, L70
Two sensors inside one tube
One sensor watches the space, the other talks to the neighbouring tubes. That is what removes the blind spot you get with a single stand-alone sensor tube.
5.8 GHz presence detection
Detects people and vehicles moving under the tube and drives the output to 100 %. Because the sensing element sits inside the lamp, nothing is mounted on the ceiling and nothing needs pairing.
2.4 GHz inter-luminaire communication
The triggered tube broadcasts to neighbouring luminaires within roughly 10 m, so the whole run lights ahead of the occupant instead of one tube at a time.
Coverage geometry as published for the Sensor LEDtube G2: recommended mounting height h = 0.5-4 m, typical detection radius r ≈ 3-5 m at h = 2.8 m, inter-luminaire signal radius ≈10 m. Indicative diagram, not a measured photometric file; real coverage varies with the installation environment.
- Recommended mounting height h = 0.5 m to 4 m
- Typical detection radius r ≈ 3-5 m at h = 2.8 m
- 60 s without motion returns the tube to 20 %
- Battery-free, no software update, no grouping setup
- Detection range follows the real mounting height
- Signal range varies with the installation environment
What the automatic dimming saves
Annual consumption for the same 1,200 mm slot, measured over 8,760 hours of operation.
36 W TL-D fluorescent on a 9 W magnetic ballast
394 kWh / year
Sensor LEDtube 18 W — 8 h occupied per day
74 kWh / year
81 % lower36 W TL-D fluorescent on a 9 W magnetic ballast
394 kWh / year
Sensor LEDtube 18 W — 12 h occupied per day
95 kWh / year
76 % lowerStandard 18 W LED tube, no sensor
158 kWh / year
Sensor LEDtube 18 W — 8 h occupied per day
74 kWh / year
53 % lowerBasis: 24 h per day, 8,760 h per year, full output during the occupied hours stated and 20 % output for the remainder. Moving up from the previous generation? The PHILIPS Sensor LEDTUBE 1200 mm 14 W 1600 lm (929001399710) is still catalogued and uses the same G13 caps — see the 14 W 1600 lm version.
Why it fits a retrofit project
No controls layer, no commissioning step, no new luminaire.
Installs like an ordinary tube
Same 1,200 mm length, same G13 caps, same luminaire. No new wiring layout and no control cable to pull.
Route stays visible when empty
20 % standby keeps the floor line, the exit signs and the camera scene readable between visits.
240° wide beam
Light leaves the tube upwards and sideways, not only downwards, so a single ceiling run covers the bay evenly.
Nothing to maintain
No battery to replace, no gateway to power, no firmware to update — the sensor lives inside the lamp for its full 50,000 h.
Fit and wiring
Straight replacement of a 1,200 mm T8 lamp in an existing G13 luminaire. The tube runs on mains, so the ballast is either kept as a magnetic choke or bypassed.
Magnetic ballast luminaire (EM)
- Switch the circuit off.
- Remove the compensation capacitor to improve the power factor.
- Take out the fluorescent tube and its starter.
- Fit the PHILIPS LED starter EP in place of the fluorescent starter.
- Insert the Sensor LEDtube G2 and switch on.
Electronic ballast luminaire (HF)
- Switch the circuit off.
- Bypass the ballast and any starter.
- Rewire the L and N supply straight to the LEDtube, observing the L/N marking.
- Insert the tube in the luminaire without changing the luminaire itself.
- Switch on and confirm the tube reaches full output on detection.
Technical specifications
Values below are the published data for 929004435410. Both colour temperatures share the same electrical and sensor platform.
| Parameter | Value | |
|---|---|---|
| General | ||
| Cap-Base | G13 | |
| Bulb Shape | T8 | |
| Lighting Technology | LEDtube | |
| Wattage Equivalent | 36 W | |
| Nominal Lifetime | 50,000 h | |
| Switching Cycle | 50,000 | |
| Ambient Temperature Range | -20 to +45 °C | |
| Light Technical | ||
| Colour Code | 840 [CCT of 4,000 K] | |
| Correlated Colour Temperature | 4,000 K | |
| Colour Designation | Cool White (CW) | |
| Luminous Flux | 2,100 lm | |
| Luminous Efficacy (rated) | 116 lm/W | |
| Beam Angle | 240° | |
| Colour Rendering Index | 80 | |
| Colour Consistency | ≤6 SDCM | |
| LLMF at End of Nominal Lifetime | 70 % | |
| Photobiological Safety | RG0 (EN 62471) | |
| Operating and Electrical | ||
| Power Consumption | 18 W | |
| Voltage (Nom) | 220-240 V | |
| Input Frequency | 50 to 60 Hz | |
| Lamp Current (Nom) | 90 mA | |
| Power Factor | 0.9 | |
| Starting Time (Nom) | 0.5 s | |
| Warm-up Time to 60 % Light | 0.5 s | |
| Dimmable | No — sensor auto-dim only | |
| Energy Consumption | 18 kWh/1000 h | |
| Sensor and Control | ||
| Presence Detection | 5.8 GHz microwave | |
| Inter-luminaire Communication | 2.4 GHz, radius ≈10 m | |
| Dimming Behaviour | 100 % on motion, 20 % after 60 s | |
| Recommended Mounting Height | 0.5 m to 4 m | |
| Typical Detection Radius | 3-5 m at h = 2.8 m | |
| Battery / Gateway / App | Not required | |
| Mechanical and Housing | ||
| Bulb Finish | Frosted | |
| Bulb Material | Glass | |
| Product Length | 1,200 mm (A1 1,199.4 mm) | |
| Tube Diameter (D1) | 25.7 mm | |
| Net Weight (Piece) | 0.200 kg | |
| Quantity per Outer Box | 20 | |
| Order Code | 929004435410 | |
| Material Nr. (12NC) | 929004435410 | |
| EAN/UPC - Product | 6947830485673 | |
| EAN/UPC - Case | 6947830485680 | |
| Approval and Application | ||
| Approval Marks | RoHS compliance | |
| EU RoHS Compliant | Yes | |
| Energy Saving Product | Yes | |
| Operating Mode | EM / Mains | |
Product gallery
Product view and the three applications the tube was specified for.




Complete product lineup
Two variants, one housing. The only difference is colour temperature.
| 12NC | Description | Power | CCT | Output |
|---|---|---|---|---|
| 929004435410 | Sensor LEDtube 1200mm 18W 840 T8 G2 CN | 18 W | 4,000 K | 2,100 lm |
| 929004435510 | Sensor LEDtube 1200mm 18W 865 T8 G2 CN | 18 W | 6,500 K | 2,100 lm |
Both codes are quoted with 20 pieces per outer box. Browse the rest of the range on the PHILIPS LED tube category page.
Also from the PHILIPS Lighting range
Other linear and industrial luminaires specified alongside the Sensor LEDtube G2.
Frequently asked questions
How far does the sensor reach?
Does one tube light the whole run or only itself?
Can I keep the existing ballast in the fixture?